Product Description

R32 making up 50% of the  R410A refrigerant , R32 has a GWP of 675 (one third that of R410A), is highly energy efficient and is easy to recycle. Plus, the volumetric capacity of R32 is around 20% higher than that of R410A, which means system refrigerant volumes are lower. R32 is a single component refrigerant, meaning it is easier to reuse and to recycle. It is also relatively inexpensive to produce, is easier to handle because it doesn’t separate and utilises familiar technology, keeping costs similar.

R32: The Benefits:

  • Low GWP of 675

  • High efficiency refrigerant

  • F–Gas phasedown compliant

  • Less refrigerant volume requirement compared to R410A

  • Affordable & readily available

  • A single component refrigerant

  • Easy to handle, reuse and recycle

  • Used in our newest, state–of–the–art products

 

With a Hiseer R32 EVI inverter heat pump. you still get the performance and efficiencies needed for the buildings, using refrigerants and equipment that delivers a much lower GWP overall.

Hiseer R32 DC inverter  heat pump offers a wide heat output  . It could adjust heat output automatically according to your house heating requirement . In winter , the inverter compressor and fan motor will runs on high speed to provide more heating when ambient temperature is very low ; If your house need less heating , it will drop running frequency down to 30Hz in which condition the heat pump will consume less electric power . 

Heat pump is not just a heating system for new buildings , it can also be integrated into existing buildings that already have heating systems easily . Irrespective of whether you have a gas , oil boiler or solar panels , the heat pump switches on the 2nd heat generator according to demand for keeping lowest heating costs. 

Hiseer R32 DC Inverter  Heat Pump Advantages:

1.Save more than 30% energy than fixed frequency heat pump 
2.Soft start to protect your electric network 
3.Smooth temperature varies curve 
4.Wide heating/cooling output range 
5.Can be used in combination with heat generators such as gas ,oil or solar that existing in buildings 
6.Intelligent defrosting by reverse circulation 
7.Weather compensation function: heating / cooling curve 
8.Heating, cooling and domestic hot water 
9. SG Ready. 
10. Flow feedback Grundfos circulation pump ,saving water flow switch.

11. Wifi smart phone App. control module is optional .Control your heat pump from anywhere at any time.

12. with EVI technology, the unit still deliver 48C hot water down to minus 25 degree Celsium ambient temperature

 

Model Number RS07V/L
Heating performance Min. Nominal  Max.
Heat output/Power consumption/COP at A7/W35℃  kW 2.20/0.48/4.58  7.30/1.42/5.15 8.00/1.63/4.91
Heat output/Power consumption/COP at A2/W35℃  kW 3.00/0.96/3.13  5.94/1.44/4.12 6.12/1.59/3.86
Heat output/Power consumption/COP at A-7/W35℃  kW 3.20/1.19/2.69  4.66/1.60/2.91  5.41/1.90/2.85
Heat output/Power consumption/COP at A-10/W35℃ kW 3.76/1.53/2.46 4.62/1.67/2.76 5.33/1.97/2.70
Heat output/Power consumption/COP at A-15/W35℃ kW 3.80/1.58/2.40 4.39/1.74/2.53 4.69/1.88/2.49
Heat output/Power consumption/COP at A7/W45℃   kW 2.30/0.61/3.78 7.26/1.82/4.00 8.10/2.10/3.86
Heat output/Power consumption/COP at A2/W45℃  kW 3.20/1.07/2.98 6.88/2.02/3.40 7.20/2.28/3.16
Heat output/Power consumption/COP at A-7/W45℃   kW 3.30/1.38/2.40 5.56/2.21/2.52 6.10/2.49/2.45
Heat output/Power consumption/COP at A-10/W45℃ kW 3.36/1.53/2.20 4.97/2.19/2.27 5.62/2.58/2.18
Heat output/Power consumption/COP at A-15/W45℃ kW 3.42/1.80/1.90 4.13/2.05/2.01 4.4/2.35/1.87
Heat output/Power consumption/COP at A7/W55℃   kW 2.35/0.79/2.96 7.23/2.31/3.13 8.12/2.72/2.98
Cool output/Power consumption/EER at A35/W7℃ kW 1.90/0.73/2.60 3.51/1.63/2.16 3.98/1.99/2.00
Nominal running current at A7/W35 A 6.21
Max operating current A 16.00
Max. power consumption KW   3.60  
Power Supply   230V/1phase/50Hz
Compressor   Panasonic EVI twin rotary
Condenser   Brazed plate heat exchanger
Nominal flow heating medium m3/h 1.25
Internal pressure drop at nominal flow kPa 19
Nominal air flow m3/h 3000
Nominal fan output  W 110
Max outlet heating medium temperature 55
Refrigerant R32 filling weight g 850
Dimensions (HxWxD) mm 1005 x 1060 x 420 
Pipe connector   G1' external thread
Net Weight kg 100
Operating ambient temp. range Heating -25~35
DHW -25~43
Cooling 10~45
Sound power level LWA dB(A) 59
The above data is tested by EN14511. A7/W35℃ means air temp. 7℃,outlet water temp. 35℃  
The Sound power level is tested by EN12102        

 

F-gas information:

Model   RS07V/L
The heat pump contains
fluorinated greenhouse gases
  R32
R32 global warming potential   675
Refrigerant R32 filling weight kg 0.85
CO2 equivalent Tonnes 0.57
       
Product Image




hiseer
hiseer

R32 heat pump
R32 heat pump

hiseer heat pump
hiseer heat pump

heat pump pressure drop
heat pump pressure drop

Related Products
R410A DC inverter  heat pump 15KW single phase
R410A DC inverter heat pump 15KW single phase
DC inverter EVI heat pump 20KW
DC inverter EVI heat pump 20KW
heat pump
DC inverter EVI heat pump 10KW
R410A DC inverter  heat pump 15KW three phase
R410A DC inverter heat pump 15KW three phase

Home  |  Product Catalog  |  Certificates  |  Contact Us  |  Sitemap  |  Mobile Version
Powered by DIYTrade.com